Description
ITEM | TEST METHODS | STANDARED | |
Dimensions | Using vernier caliper(accuracy≥0.02) while avoiding short-circuit | Diameter | 11.6(-0.15)mm |
Height | 3.00(-0.20)mm | ||
Off-load
voltage |
Using multimeter(accuracy≥0.25%)internal resistance≥1MΩ |
≥3.20V |
|
Instantaneous
Short-circuit current |
Time of short-circuit should be less than 0.5 Second and avoid repeated test within half an hour |
≥200mA |
|
Appearance | Eyeballing | Bright, clean, no rust, no leakage, and no flaw | |
Capacity | Continuously discharge for 8 hour with load 4.7K, temperature at 20-25℃,humidity at 65±20% till 2.0v end-voltage(for fresh battery only: within 3 months) |
≥70h |
|
Vibration test |
Put battery on the platform of the vibrations
Machine, start the machine and adjust the Frequency form 10 times per minute to 15 Times per minute. keep it running for an hour |
Characteristics keep stability |
|
Leakage at
high temperature |
Stored under temperature(45℃)for 30 days |
Leakage rate≤0.5% |
|
Over
Discharge Test |
After 2.0v end-voltage, continuously discharged for 5 hours | No leakage allowed |