CR2 Lithium Battery

Model CR2
Nominal

Voltage

3V
Nominal

Capacity

900mAh
Dimension Φ15.3×27.0mm
Weight 10.2g
Temperature

range

-30~60℃
Send Inquiry
Description

Description

1.   Model Number

2.   Nominal Voltage

3.   Nominal Capacity

 

 

 

4.   Standard Discharge Current

5.   Max. Continuous Discharge Current

6.   Construction

6.1   Appearance, Dimensions

 

 

6.2   Weight

7.  Performance

7.1  Open Circuit Voltage

7.2  Duration 1. ( at 20±2℃ )

7.2.1  Pulse Discharge Conditions

Pulse Current

One Cycle

Cut Off V.

7.2.2 Max.Pulse current

7.3  Duration 2. ( at -20±2℃ )

7.3.1  Pulse Discharge Conditions

Pulse Current

One Cycle

Cut off V.

7.4  Impedance

7.5  Vibration Resistance

 

7.6  Temperature Range

 

7.7  Leakage Resistance

 

: CR2 1A

: 3 V

: 900 mAh

(Nominal capacity is based on standard

drain and cutoff Voltage down

to 2.0V at 20℃)

: 20 mA

: 1000 mA (at 20℃)

 

: There shall be no noticeable deformation.

The dimensions shall be according to the

attached drawings.

: Approx. 10.2g

 

: Min. 3 V

 

: Population Mean ≥ 950 cycles

: 900 mA

: 3 seconds on, 27 seconds off

: 1.55 V

:3000mA

 

: Population Mean ≥ 500 cycles

: 900 mA

: 3 seconds on, 27 seconds off

: 1.2 V

: Max. 1.0 Ω

: Deterioration of performance shall not

occur.

: Discharge  -30 to 60℃

Storage    -30 to 60℃

: The battery shall not show leakage or

salting which harms performance.

  1. PTC ( Positive Temperature Coefficient ) Device Performance
 8.1  Appearance

 

8.2  Resistance

: There shall be no noticeable deformation

and/or scratches.

: The resistance shall be between 15 to 80

mΩ ( no load ).

When 5 A flows, the resistance shall be

more than 10 Ω before 80 seconds.

  1. Test Conditions, Measuring Instruments and Measuring Methods
9.1   Test Conditions

 

 

9.2   Measuring Instruments

i )  Volt Meter

 

ii)  Battery Impedance Meter

 

iii)  Caliper

iv)  Balance

v )  Ohm Meter

 

9.3   Measuring Method

i )  Outer Dimensions

 

ii)  Weight

 

iii) Appearance

 

iv)  Open Circuit Voltage

 

v )  Operating Time ( Duration )

 

 

vi)  Battery Impedance

 

vii) Vibration Resistance

 

 

 

viii) Leakage Resistance

 

 

 

 

 

 

ix)  PTC Device Performance

: If not otherwise specified,

Temperature : 25±5℃

Humidity    : 65±10%

 

: Internal Impedance : More than 10MΩ

Accuracy     : Less than 0.5%

: Sine wave A,C,method ; 1 kHz 0.1mA

( National Digital milliohm Meter [VP-2811A] )

: Accuracy    ; less than 1% by JIS

: Sensitivity   ; More than 100 mg

: Sine wave A.C.method ; 1 kHz 0.1mA

( National Digital milliohm Meter [VP-2811A] )

 

: This shall be measured with the caliper

described in Item 9.2 iii ).

: This shall be measured with the balance

described in Item 9.2 iv ).

: Deformation or tarnish shall be visually

checked.

: This shall be measured with the volt

meter described in Item 9.2 i ).

: Operating time shall be measured with

cycles until terminal voltage

reaches the specified cut-off voltage.

: This shall be measured by the meter

described in Item 9.2 ii ).

: Amplitude ; 2 mm

Number of Vibrations : 1000 rpm.

Directions ; X,Y,Z

Time ; 30 minutes in each direction

: Heat cycle test

Leakage, appearance and outer dimensions

shall be checked after 10 cycles

according to MIL-STD-202E-106D.

The battery shall be kept in a dry

place. It should not show any dew point

when stored in this condition.

: This shall be measured with the

instrument described in Item 9.2 v).

  1. Precautions for use
  • A battery shall not be stored at temperatures in excess of 45℃. Storage at less than 30℃ is recommended. Storage at less than -30℃ can deform the plastic parts and may cause a leakage. To prevent self-discharge caused by corrosion, or decrease of insulation, humidity during storage shall be less than 70%.
  • The battery has an explosion resistant construction. But the following cautions should be taken. because combustible materials such as lithium metal and organic electrolyte are contained in the battery.

* Do not short circuit.

* Do not dispose in fire.

* Do not charge.

* Do not disassemble.

  • Keep away from heat sourse of flame.
  • The battery shall not be washed by ultrasonic wave washer.
Specifications & data sheet

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames.Consequat net

Vestibulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames.Consequat netus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac vestibulum amet elit